RIKEN LOAD MONITORING RLG-2/4
2 min readMultifunctional Load Monitoring System
RLG-2/4
Multiple alarm functions incorporated high performance automatic Load Monitoring System
RLG has the function of detecting the press load with a strain gauge. It displays the accurate load during press processing, and output stop signals and stops a press machine immediately when abnormality is detected. Multiple detection modes incorporated cannot be ignored when there are eccentric loads for each stroke, and furthermore, load monitoring extends the life of dies, prevents friction and wear of presses, also promotes quality control and rationalization.
Features
- Improvement of labor efficiency:
Multiple load monitoring function. - Easy to read digital display:
The tonnage of the load to be processed at each side is displayed digitally for every channel and the total tonnage of the pressurized load is displayed at the center. The operator can check the pressurized load during the stamping and get a good grasp of the load balance from the pressurized load tonnage displayed for each channel. It is instrumental to the protection of the press machine and dies. - Three-Selector Changeover Function:
Three monitoring functions (Trend Alarm, Adaptive Alarm and Area Alarm) can be designated by changing over the switches. One of the monitoring functions suited for the operation can be used. - Simple Quality Control:
The load variation during the stamping is displayed on the LED bar, which allows the operator to easily check the deviation from the common difference. Green and orange lights will come on when the value is within the upper and lower limits; a red light will come on if the value exceeds the upper and lower limits. The operator can check for any variation during the operation (when the press machine is running) hence, it is useful for quality control purposes. - It will detect double stamping and feeding errors:
It will stop the press machine to prevent losses when it detects an unusual load generated by double stamping or a feeding error.
Specifications
●Electrical Specifications | Power supply | 90-264 VAC |
---|---|---|
Current consumption | 100mA-220 VAC / 115mA-200 VAC | |
No.of channels | 2 channels(RLG-2) / 4 channels | |
A/D conversion method | 12 bit | |
Normal mode rejection | 50db at 2,000 gain (between + innput and – input) | |
Calibration | Manual calibration | |
Isolation | 500VDC continuous between inputs and chassis ground | |
●Environmental Specificatins | Working temperature | 0℃-60℃(32°F-140°F) |
●Input Specifications | Input type | Strain gauge (350Ω, 700Ω) |
Input impedance | 1K | |
Low range gain | Max. gain 1176 | |
Cal. resistor(140k-ohm) | Min. gain 54 | |
High range gain | Max. gain 6959 | |
Cal. resistor(1meg-ohm) | Min. gain 347 | |
Display resolution | Up to 0.1% of full scale | |
Overall module accuracy | 1% of full scale | |
A/D sample rate | 100 microseconds | |
●Output Specifications | Alarm relay | Dry contact (10A 240VAC) |
Untuk informasi harga, Penawaran dan Stok Barang silahkan hubungi kami di bawah ini:
PT. HIKMAH JAYA SENTOSA
JL. Puskesmas No 36 Kebagusan Pasar Minggu
Jakarta Selatan 12520 Indonesia
: 62-21 2278 3971, 781 9193
: 62-21 2270 1404
: 0852 1673 8806
: marketing1@hikmahjayasentosa.com
: marketing2@hikmahjayasentosa.com
: marketinghjs@imail.co.id
Sales Dept.
Rahmat Khaidir :
: 0812 8396 8279 – 0813 9902 6841